Smart High Side Switch
The NSE34xxx/NSE35xxx series high-side switches are designed for driving various traditional resistive, inductive, and halogen lamp loads in systems like automotive BCMs, while also being well-suited for handling large capacitive loads commonly found in first and second-level distribution in Zonal Control Units (ZCUs). These series offer options for 1, 2, or 4 channels and are available in HSSOP-16/HSSOP-14 packages, with an Rds(on) range from 8mΩ to 140mΩ. The chips feature precise current sensing, ideal for fault diagnosis, protection, and real-time monitoring of load currents. Additionally, the NSE34xxx/NSE35xxx series incorporate comprehensive protection mechanisms, including overcurrent/short-circuit protection, overtemperature protection, overvoltage protection, ground and power loss protection, reverse polarity protection, and open-load detection.The NSE34xxx and NSE35xxx series products are AEC-Q100 qualified and certified to AEC-Q100-012 level A, ensuring over a million cycles of short-circuit and overcurrent protection.
View All Products
show 27 devices
Part Number | ECAD Model | Ambient Temperature | Number of Channels | MOS Impedance | Protection | Feature | Application | Package |
---|---|---|---|---|---|---|---|---|
NSE34025Q | -40℃~125℃ | 4CH | 25mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34050Q | -40℃~125℃ | 4CH | 50mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34140Q | -40℃~125℃ | 4CH | 140mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34050D | -40℃~125℃ | 2CH | 50mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34050S | -40℃~125℃ | 1CH | 50mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34140D | -40℃~125℃ | 2CH | 140mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34140S | -40℃~125℃ | 1CH | 140mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34025D | -40℃~125℃ | 2CH | 25mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34025S | -40℃~125℃ | 1CH | 25mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34012D | -40℃~125℃ | 2CH | 12mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34012S | -40℃~125℃ | 1CH | 12mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34008D | -40℃~125℃ | 2CH | 8mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE34008S | -40℃~125℃ | 1CH | 8mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-16 | |
NSE35120DA | -40℃~125℃ | 2CH | 60mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35200DA | -40℃~125℃ | 2CH | 60mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35040DA | -40℃~125℃ | 2CH | 20mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35040SA | -40℃~125℃ | 1CH | 20mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35080DA | -40℃~125℃ | 2CH | 20mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35012DA | -40℃~125℃ | 2CH | 12mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35012SA | -40℃~125℃ | 1CH | 12mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35020DA | -40℃~125℃ | 2CH | 12mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35030DA | -40℃~125℃ | 2CH | 12mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35010DA | -40℃~125℃ | 2CH | 10mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35010SA | -40℃~125℃ | 1CH | 10mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35008DA | -40℃~125℃ | 2CH | 8mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35008SA | -40℃~125℃ | 1CH | 8mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 | |
NSE35008SP | -40℃~125℃ | 1CH | 8mΩ | Overcurrent protection Short-circuit protection Overvoltage protection Over-temperature protection Lost ground protection Lost power protection Reverse polarity protection | Open circuit diagnosis Support inductive loads | BCM ZCU | HSSOP-14 |
For more product information, please contact us.